Luigi Carassale ::: Structural Dynamics & Monitoring
PROJECTS
FE calculations for failure analysis and retrofitting. Shuwaihat desalination plant.
Vibration measurements and analysis for troubleshooting in rotating machines in Ras Laffan Vibration measurements and analysis for troubleshooting in rotating machines in Shuweihat (Abu
2006 - Fisia Italimpianti

Finite Element Modeling of pump frames, calibration with experimental vibration measurements and numerical verification of retrofitting solutions. Non-linear modeling of the contact surface of the bolted flange, evaluation of the stress amplitude in bolts and relevant parts of the frame. Fatigue analysis by hot-spot method.

Cesare Rizzo (DINAEL, University of Genova)
Chiara Calderini (DICAT, University of Genova)



FE Model of column pipe and discharge elbow


FE Model - Detail of the bolted flange. Links to model bolts and contact elements on the flange contact surface.


Stress analysis calibrated by in-field vibration measurements


Flange contact pressure at the characteristic amplitude of vibration


Bolt stress at the characteristic amplitude of vibration


Numerical verificatio of column pipe modifications


Modified structure